17AM033A5 Auto Reset Thermal Fuse 17AM035A5thermal Fuse 17AM034A3 Temperature Controller Auto Reset

Ask Latest Price
Video Channel
Brand Name :HENG HAO
Model Number :17AM
Certification :UL TUV CQC
Place of Origin :CHINA
MOQ :1000pcs
Price :USD
Payment Terms :TT FOB SZ, T/T
Supply Ability :10000000pcs per month
Delivery Time :10WORKDAYS
Packaging Details :5000pcs per carton
Rating and Currents :AC-125V 15A; AC-250V 10A, DC-16V 20A
life time :10000 times
use for :17AM thermal protector is applicable to all kinds of Motor, commentator for fluorescent lamp, transformer, Laminator, lamps and lighting, transformers, cover sealing machine & various of household appliances
switch type :auto reset normally closed type
Name :Thermal overload protection switch
Operating temperature range :50-180°C
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

17AM033A5 Auto Reset Thermal Fuse 17AM035A5thermal Fuse 17AM034A3 Temperature Controller Auto Reset

17AM033A5  Auto Reset Thermal Fuse 17AM035A5thermal Fuse 17AM034A3 Temperature Controller Auto Reset

  1. 17AMH thermostat’s Principle and structure

17AM is an excess-current thermal protector with compact design, Quick and accurate action, we can rivet different types of leads according to customers' requirements.

  1. 17AM thermal protector’s Specification
    1. Electrical Rating and Currents: AC-125V 15A; AC-250V 10A, DC-16V 20A
    2. Contact life cycles: AC-125V 15A, AC-250V 10A more than 10,000 Cycles; AC-125V 5A more than 100,000 Cycles
    3. Operating temperature range: 50-180°C
    4. Temperature tolerance: ±2°C±3°C±5°C
    5. Reset temperature: 10~45 degrees in off temperature decline.
    6. Working times: Over 10000 times
    7. Code syste

17AM XXX A / B 5 A,B,C,D………..Z

(17AMH): The number of product series

(XXX): Trip off temperature in °C Code

(A / B): A: Terminals in the same direction / B: Terminals in the opposite direction

(5): OFF Temperature Tolerance Code

(A, B, C, D………..Z): Different type of connecting wire

  1. Trip off temperature in °C Code
Degrees °C Code Degrees °C Code Degrees °C Code Degrees °C Code
55°C 018 90°C 025 125°C 032 160°C 039
60°C 019 95°C 026 130°C 033 165°C 040
65°C 020 100°C 027 135°C 034 170°C 041
70°C 021 105°C 028 140°C 035 175°C 042
75°C 022 110°C 029 145°C 036 180°C 043
80°C 023 115°C 030 150°C 037
85°C 024 120°C 031 155°C 038

17AM033A5  Auto Reset Thermal Fuse 17AM035A5thermal Fuse 17AM034A3 Temperature Controller Auto Reset

The thermal protection switch is normally located on the A/C compressor housings. It. is used to prevent compressor damage (overheat) through internal friction. This switch senses the compressor case temperature and once this case. temperature reaches a predetermined figure the electrical circuit to the compressor.

Right Answer is:

Thermal protection switch protects against the overload. To create this type of overload, a bra shaft is placed inside a brass tube. In these overload relays (also referred to as “solder pot relays”), the motor current passes through a small heater winding.
  1. Product Drawing

17AM033A5  Auto Reset Thermal Fuse 17AM035A5thermal Fuse 17AM034A3 Temperature Controller Auto Reset

17AM033A5  Auto Reset Thermal Fuse 17AM035A5thermal Fuse 17AM034A3 Temperature Controller Auto Reset

  1. 17AM temperature protector’s Application

all kinds of Motor, commentator for fluorescent lamp, transformer, Laminator, lamps and lighting, transformers, cover sealing machine & various of household appliances

  1. 17AM thermostat’s A/°C and A/T Graph:
  2. 17AMH Thermal protector / 17AMH Thermostat / 17AM temperature protector / instead of KLIXON 17AM thermal protector

  3. 17AMH thermostat’s Principle and structure
  4. 17AM is an excess-current thermal protector with compact design, Quick and accurate action, we can rivet different types of leads according to customers' requirements.

    2. 17AM thermal protector’s Specification

    2.1. Electrical Rating and Currents: AC-125V 15A; AC-250V 10A, DC-16V 20A

    2.2. Contact life cycles: AC-125V 15A, AC-250V 10A more than 10,000 Cycles; AC-125V 5A more than 100,000 Cycles

    2.3. Operating temperature range: 50-180°C

    2.4. Temperature tolerance: ±2°C±3°C±5°C

    2.5. Reset temperature: 10~45 degrees in off temperature decline.

    2.6. Working times: Over 10000 times

    2.7. Code syste

    17AM XXX A / B 5 A,B,C,D………..Z

    (17AMH): The number of product series

    (XXX): Trip off temperature in °C Code

    (A / B): A: Terminals in the same direction / B: Terminals in the opposite direction

    (5): OFF Temperature Tolerance Code

    (A, B, C, D………..Z): Different type of connecting wire

    2.8. Trip off temperature in °C Code

    Degrees °C Code Degrees °C Code Degrees °C Code Degrees °C Code
    55°C 018 90°C 025 125°C 032 160°C 039
    60°C 019 95°C 026 130°C 033 165°C 040
    65°C 020 100°C 027 135°C 034 170°C 041
    70°C 021 105°C 028 140°C 035 175°C 042
    75°C 022 110°C 029 145°C 036 180°C 043
    80°C 023 115°C 030 150°C 037
    85°C 024 120°C 031 155°C 038
    17AM033A5  Auto Reset Thermal Fuse 17AM035A5thermal Fuse 17AM034A3 Temperature Controller Auto Reset